Summary of Contents for Graco LineLazer V 3900 Standard Series
Page 1
Be familiar with the controls and the proper usage of the equipment. Save these instructions. Related Manuals: 3A3389 Parts 311254 309277 Pump 3A3428 Auto-Layout Applications Methods ti27920a Use only genuine Graco replacement parts. The use of non-Graco replacement parts may void warranty.
LineLazer V LiveLook Display LineLazer V LiveLook Display Standard Series STRIPING SCREEN MEASURE MODE SETTING/INFO MEASURE MODE CALIBRATION 1950 psi 0.00 ¹ SETTINGS 0.00 ¹ ¹ 0.00 ¹ INFORMATION 0.00 ¹ 46 gal 0.00 ¹ FRE GLOBAL 0.00 ¹ Displays: 3A3388H Operation...
Page 4
LineLazer V LiveLook Display Initial Setup (Standard Series) US Units Pressure = psi Volume = gallons The initial setup prepares the striper for operation based Distance = feet on a number of user entered parameters. Language Line Thickness = mil selections and the units of measure selections can be set before you start or changed later.
Page 5
LineLazer V LiveLook Display 3. Press to select Setup/Information. 6. Push to start calibration. ti27826a 7. Move striper forward. Keep unit aligned with steel tape. 8. Stop when chosen part of unit aligns with 26-ft (8m), or distance entered, on steel tape (25-ft./ 7.6m ti27827a distance).
Page 6
LineLazer V LiveLook Display Striping Mode (Standard Series) ti27889a Operating in Striping Mode Ref. Description 1. Make sure engine is running. Resets Distance, Gallons, Mils Job logging 2. Set pump switch to ON. Scroll between menu screens Line width adjustment buttons Auto gun buttons MIL thickness.
Page 7
LineLazer V LiveLook Display Measure Mode (Standard Series) 2. Press and release . Move striper forwards or backwards. (Moving backwards is a negative Measure Mode replaces a tape measure to measure distance.) distances when laying out an area to be striped. 1.
Page 8
LineLazer V LiveLook Display Setup/Information to select Setup/Information. Press to select Language. See Language, page 26. See Calibration, page 26. See Settings, page 31. See Information, page 32 ti27835a 3A3388H Operation...
Page 9
LineLazer V LiveLook Display Settings to select Setup/Information. Press open Settings Menu. Chooses the machine type. Necessary for accurate gallon counting. to set time and date. Set units with to adjust screen contrast to the desired value. ti27839a 3A3388H Operation...
Page 10
LineLazer V LiveLook Display Information to select Setup/Information. Press open Information Menu. Displays and logs life data and striper information. View and test functionality of components. Stroke Counter Touch Pad Buttons Pressure Transducer Engine Voltage Distance Sensor Battery Voltage Logs last four error codes that occurred. Code Description 02 = Over pressure 03 = No transducer detected...
Page 11
HP Auto Series HP Auto Series ti27942a 3A3388H Operation...
Page 12
LineLazer V LiveLook Display LineLazer V LiveLook Display HP Auto Series CHOOSE BETWEEN HOW THE RED TOGGLE BETWEEN SKIP CYCLE BUTTON ACTUATES THE GUN AND LINE WIDTH DISPLAY ON SCREEN = Hold the button to spray, release to stop (Manual). = Press for one time shot when in Skip Mode.
Page 13
LineLazer V LiveLook Display Initial Setup (HP Auto Series) US Units Pressure = psi Volume = gallons The initial setup prepares the striper for operation based Distance = feet on a number of user entered parameters. Language Line Thickness = mil selections and the units of measure selections can be set before you start or changed later.
Page 14
LineLazer V LiveLook Display 6. Press and release gun trigger control to start 3. Press to select Setup/Information. calibration. ti27912a 7. Move striper forward. Keep laser dot on steel tape. 8. Stop when laser aligns with 26-ft (8m) or distance entered on steel tape (25-ft./7.6m distance).
Page 15
LineLazer V LiveLook Display Striping Mode (HP Auto Series) 1450 psi 30.8 ¹ 0.0 gal ti27844a Ref. Description Operating in Striping Mode Select a “Favorite”, press for less than one second. Striper must be running before activating gun trigger Save a “Favorite”, press and hold for more than control.
Page 16
LineLazer V LiveLook Display Measure Mode (HP Auto Series) 2. Press and release gun trigger control. Move striper forwards or backwards. (Moving backwards is a negative distance.) Measure Mode replaces a tape measure to measure distances when laying out an area to be striped. 1.
LineLazer V LiveLook Display Layout Mode 2. Use gun activation buttons to select guns. Layout Mode is used to calculate and mark parking lot stalls. 1. Use to select Layout Mode. ti27918a 3. Press and release gun trigger control and move striper forward.
LineLazer V LiveLook Display Stall Calculator 2. The most recent length measured in Measure Mode is automatically displayed. Press gun trigger control to start a new measurement. Press again to stop Stall Calculator is used to set the stall size. The striper measuring.
LineLazer V LiveLook Display Angle Calculator 2. Dot spacing (B) and offset (C) are calculated based on the parameters entered: Angle Calculator is used to determine the offset value Stall angle and dot spacing value for a layout. Stall depth Stall size (width) 1.
Page 20
LineLazer V LiveLook Display 5. Press and release gun trigger control to start 4. Press to transfer calculated dot spacing marking stall size dots. Press and release gun distance to Layout Mode. Save this value in trigger control to stop marking. favorites if desired.
Page 21
LineLazer V LiveLook Display Setup/Information to select Setup/Information. Press to select Language. See Language, page 35. See Measure Mode (HP Auto Series), page 38. See Settings, page 44. See Information, page 45. See Marker Layout Mode, page 46. ti27858a 3A3388H Operation...
Page 22
LineLazer V LiveLook Display Settings to select Setup/Information. Press to open Settings Menu. Chooses the machine type. Necessary for accurate gallon counting. to set time and date. Needed for accurate Data Logging. Set units with to adjust screen contrast to the desired value. For programmed skip lines, press to choose: Paint first...
Page 23
LineLazer V LiveLook Display Information to select Setup/Information. Press open Information Menu. Displays and logs life data and striper information. View and test functionality of component Stroke Counter Touch Pad Buttons Pressure Transducer Engine Voltage Distance Sensor Battery Voltage Clutch Solenoid 1 Solenoid 2 Battery charger state...
Page 24
LineLazer V LiveLook Display Marker Layout Mode 4. Set gun switch to skip line or solid line. The Marker Layout Mode feature sprays a dot or a series of dots to mark an area. 1. Use to select Setup/Information. Press to open Marker Layout Mode.
LineLazer V LiveLook Display Data Logging The LLV control is equipped with Data Logging, which allows the user to recall job data and export the data from the machine to a USB drive. 1. Press the to open the Data Logging pop up window.