Installation

1. Install vertical gun mount onto gun bar.
NOTE: Make sure all hoses, cables, and wires are
properly routed through brackets.

Trigger Sensor Adjustment

1. Start striper engine. Engage trigger. Spray icon
should appear simultaneously with start of fluid
spray.
Standard Series
1490
30. 8
0. 0
9
HP Auto Series
1490
30. 8
0. 0
9
ti27940a
3A3426A Operation
ti27801a
0
mph
6
0
mph
6
No fluid spray
2. Turn screw in handle clockwise if spray icon
appears before fluid spray starts.
No spray icon
3. Turn screw in handle counterclockwise if fluid spray
starts before spray icon appears.
4. Continue adjusting screw in handle until timing of
spray icon and fluid spray are synchronized.
ti27883a
Gun Placement
ti27802a
ti27803a
19