Grounding Procedure (For Flammable Flushing Fluids Only); Pressure Relief Procedure - Graco LineLazer V 200HS Operation

Airless line stripers, standard series and high production (hp) series
Hide thumbs Also See for LineLazer V 200HS:
Table of Contents

Advertisement

Grounding Procedure
(For Flammable Flushing Fluids
Only)
This equipment must be grounded to reduce the risk of
static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
1. Position striper so that the tires are not on
pavement.
2. Striper is shipped with a grounding clamp.
Grounding clamp must attach to grounded object
(e.g. metal sign post).
3. Disconnect grounding clamp after flushing is
complete.

Pressure Relief Procedure

This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid
and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
3A3426EOperation

Grounding Procedure (For Flammable Flushing Fluids Only)

1. Perform Grounding Procedure (For Flammable
Flushing Fluids Only), page 11.
2. Set pump switch to OFF. Turn engine OFF.
3. Turn pressure control to lowest setting. Trigger all
guns to relieve pressure.
4. Engage all gun trigger locks. Turn prime valve
down.
ti27615a
5. If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved:
a. VERY SLOWLY loosen the tip guard retaining
nut or the hose end coupling to relieve pressure
gradually.
b. Loosen the nut or coupling completely.
c. Clear the obstruction in the hose or tip.
ti27504a
ti28013a