12 MAINTENANCE & TROUBLESHOOTING
12.4 Replacement of Fuses
To protect the FS-1570 from overcurrent and equipment fault, two fuses are provided in
the PR-300 Power Supply Unit. If a fuse blows, find the cause before replacing it. If it
blows again after replacement, request service.
CAUTION
Use the proper fuse.
Use of the wrong fuse can cause serious
damage to the equipment and void the
warranty.
Unit
Power Supply Unit PR-300
FUSE
100V 10A
220V 5A
ON
OFF
AC IN
L
N
G
Note: The Power Supply Unit PR-850A, used with the FS-2570, does not have a fuse but
a circuit breaker. If the breaker has tripped, find the reason before resetting the
breaker (upward position).
BREAKER
POWER
ON
ON
OFF
AC INPUT 50/60Hz
12-4
10 A (100 VAC) or 5A (200 VAC)
and 20 A (24 VDC)
125V 20A
ON
OFF
DC IN
DC OUT
+
-
+
-
PR-300
DC OUTPUT
PR-850A
Fuse
PR-300
24V
+
-