7.24 Upgrade the firmware and project
Restoring the last update
The current firmware version is displayed at "Restore last update" in the "Manage config"
area. If an older version of the firmware is available as a backup, this version is also
displayed with its ID and in this case, you can downgrade the firmware back to this backup
version.
1. If a reset is not to be initiated when restoring the last version, activate the "No Reset"
checkbox.
2. Click "Restore last update".
The last version of the firmware is then restored.
7.24.3

Updating the firmware

Requirements
● An existing drive project
● A memory card with the latest firmware
● The STARTER commissioning tool with new firmware on the programming device
(PG/PC)
● PG/PC is connected to the Control Unit (target device)
Danger to life through software manipulation when using removable storage media
The storage of files on removable storage media involves a high risk of infection, e.g. via
viruses or malware. As a result of incorrect parameterization, machines can malfunction,
which in turn can lead to injuries or death.
• Protect the files on removable storage media against harmful software through
378
WARNING
appropriate protective measures, e.g. virus scanners.
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4