Basic information about the drive system
13.7 Parameterizing using the BOP20 (Basic Operator Panel 20)
Status indicator
The operating display for each drive object can be set using p0005 and p0006. Using the
operating display, you can change into the parameter display or to another drive object. The
following functions are possible:
● Changing the active drive object
– Press key "FN" and "Arrow up" -> the drive object number at the top left flashes
– Select the required drive object using the arrow keys
– Acknowledge using the "P" key
● Parameter display
– Press the "P" key.
– The required parameters can be selected using the arrow keys.
– Press the "FN" key -> "r00000" is displayed
– Press the "P" key -> changes back to the operating display