Omron CPM2C Operation Manual page 108

Hide thumbs Also See for CPM2C:

Advertisement

Name
Assigning expansion
instruction function codes
Setting a program memory
address
Reading a program memory
address
Instruction search
Bit operand search
Inserting and deleting
instructions
Entering or editing programs
Checking the program
Bit, digit, word monitor
Multiple address monitor
Differentiation monitor
Binary monitor
3-word monitor
Signed decimal monitor
Unsigned decimal monitor
3-word data modification
Changing timer, counter SV 1
Changing timer, counter SV 2
Hexadecimal, BCD data
modification
Binary data modification
Signed decimal data
modification
Unsigned decimal data
modification
Force set/reset
Clear force set/reset
Hex-ASCII display change
Displaying the cycle time
Reading and setting the clock Reads or sets the internal clock.
4-4-2 Clearing Memory
Reads or changes the function codes assigned to expansion instructions
Sets the specified program memory address when reading, writing,
inserting and deleting programs.
Reads the contents of the Program Memory. Displays the status of the
currently displayed bit in PROGRAM and MONITOR modes.
Finds occurrences of the specified instruction in the program.
Finds occurrences of the specified operand bit in the program.
Inserts or deletes instructions from the program.
Overwrites the contents of the current Program Memory to either input a
program for the first time or to change a program that already exists.
Checks for programming errors and displays the program address and
error when errors are found.
Monitors the status of up to 16 bits and words, although only 3 can be
shown on the display at one time.
Monitors the status of up to 6 bits and words simultaneously.
Monitors the up or down differentiation status of a particular bit.
Monitors the ON/OFF status of any word's 16 bits.
Monitors the status of three consecutive words.
Converts the contents of the specified word from signed hexadecimal
(two's complement format) to signed decimal for display.
Converts hexadecimal data in a word to unsigned decimal for display.
Changes the contents of one or more of the 3 consecutive words
displayed in the 3-Word Monitor operation.
Changes the SV of a timer or counter.
Makes fine adjustment changes to the SV of the timer or counter.
Changes the BCD or hexadecimal value of a word being monitored.
Changes the status of a word's bits when the word is being monitored.
Changes the decimal value of a word being monitored as signed decimal
data, within a range of --32,768 to 32,767. The contents of the specified
word are converted automatically to signed hexadecimal (two's
complement format.)
Changes the decimal value of a word being monitored as unsigned
decimal data, within a range of 0 to 65,535. A change into hexadecimal
data is made automatically.
Forces bits ON (force set) or OFF (force reset.)
Restores the status of all bits which have been force set of reset.
Converts word data displays back and forth between 4-digit hexadecimal
data and ASCII.
Displays the current average cycle time (scan time.)
This operation is used to clear all or part of the Program Memory and data areas,
as well as the contents of the Programming Console's memory. This operation is
possible in PROGRAM mode only.
RUN
No
No
Before beginning to program for the first time or when installing a new program,
clear all areas.
Function
MONITOR
PROGRAM
OK
Section
4-4
Page
96
96
96
100
100
101
97
102
103
104
104
105
106
106
107
107
108
108
109
109
110
111
111
112
113
113
113