Table 10: 9012FC and 9012FCHS I/O cooling module LED status
LED Color
Green
Amber (both red
and green LED
turned on)
Red

9012RC SF cooling module

The Virtual Services Platform 9012 requires two 9012RC SF cooling modules. You must install the
SF cooling modules in the back of the chassis. The SF cooling modules provide cooling based on
the demand of the SF modules. Each cooling module includes two fans.
The SF cooling modules are hot swappable. You can replace them, one at a time, without turning off
the Virtual Services Platform 9000.
The following figure shows the SF cooling module for the chassis.
Figure 5: SF cooling module partially removed
The following table provides the dimensions for the 9012RC SF cooling module.
March 2015
Status
Normal
Warning
Fail
Comments? infodev@avaya.com
Description
All fans are functional and spinning above the program
controlled FAN_FAULT_THRESHOLD register settings.
One of the fans is not functioning properly. Either it is
spinning below the FAULT threshold setting or does not
spin at all. The fan tray can still provide enough cooling
by increasing the fan speed of the remaining fans.
Two or more fans are not working, either from spinning
too slowly or not at all. The fan tray may not provide
enough cooling.
Installing Cooling Modules in Avaya VSP 9000
Virtual Services Platform 9012
27