If the parameterized reboot delay time is 0.0, the function is deactivated.
System variables
The time remaining until the NC is rebooted can be read in the system variable:
$AN_REBOOT_DELAY_TIME
While no request for a reboot of the NC (NC reset) has been triggered from the user interface,
the system variable has the value 0.0.
A value greater than 0.0 indicates that a reboot request (NC reset) has been triggered from
the user interface and also the time remaining in the NC or PLC until the reboot.
Application example
Evaluating the system variables in a static synchronized action
Condition part: Check for a value greater than 0.0 because then a request for a reboot of the
NC (NC reset) has been made from the user interface.
Action part: e.g. triggering "safe standstill" as part of the "Safety Integrated" function.
5.11
Data lists
5.11.1
Machine data
5.11.1.1
General machine data
Number
Identifier: $MN_
10050
SYSCLOCK_CYCLE_TIME
10070
IPO_SYSCLOCK_TIME_RATIO
10082
CTRLOUT_LEAD_TIME
10083
CTRLOUT_LEAD_TIME_MAX
10088
REBOOT_DELAY_TIME
18342
MM_CEC_MAX_ POINTS[t]
5.11.1.2
Channelspecific machine data
Number
Identifier: $MC_
20150
GCODE_RESET_VALUES
Extended Functions
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
Description
Basic system clock cycle
Factor for interpolator clock cycle
Shift of setpoint transfer time
Maximum permissible setting for shift of setpoint trans‐
fer time
Reboot delay
Maximum number of interpolation points of sag com‐
pensation
Description
Reset G groups
K3: Compensations
5.11 Data lists