Replace Release 9R Circuit Packs - Avaya DEFINITY Series Installation And Maintenance Manual

Enterprise communications server
Hide thumbs Also See for DEFINITY Series:
Table of Contents

Advertisement

DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN 555-233-121
1
SREPN Installation

Replace Release 9r circuit packs

Administering the sync source
NOTE:
Do not administer a trunk on the SREPN as the synchronization source for
the Release 9r. If the system goes into the survive mode, the Release 9r
loses its sync source.
To administer the sync source for the SRP:
1. On the SRP system, type change synchronization and press
2. Enter a DS1 trunk circuit pack on the SRP as the primary sync source.
3. Press
4. When all administration is completed on the SRP, type save translation
and press
5. Return the TN2301 switch to the AUTO position.
Replace Release 9r circuit packs
If the Release 9r has the TN574 DS1CONV circuit pack:
1. Replace the TN574 DS1CONV circuit pack with the TN1654 DS1CONV
circuit pack.
2. If you have a TN573 SNI circuit pack, replace it with a TN573B SNI circuit
pack.
to effect the changes.
Enter
NOTE:
When the system is in the survive mode, the synchronization of the
SRP comes from the DS1 trunk circuit pack. When the system is in
the normal mode, the synchronization of the SRP reverts back to the
tone clock and causes a sync alarm in the alarm logs of the SRP.
.
Enter
Issue 2
November 2000
1-23
.
Enter

Advertisement

Table of Contents
loading

Table of Contents