DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN 555-233-121
1
SREPN Installation
Administer the Release 9r and SRP
Administering the maintenance parameters
Page 1 of the system-parameters maintenance form contains 2 fields that must be
administered for the abbreviated alarm report.
the First OSS Telephone Number: and Second OSS Telephone
Number: fields that are administered with offsite notification numbers. The
Abbrev Alarm Report? fields associated with these numbers must be set to
avoid unnecessary notification calls.
1. Set the two Abbreviated Alarm Report fields to y and press
change system-parameters maintenance
OPERATIONS SUPPORT PARAMETERS
First OSS Telephone Number: 9~p5380532
Second OSS Telephone Number: 9~p5380533
Alarm Origination to OSS Numbers: both
Cleared Alarm Notification? y
Customer Access to INADS Port? y
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Control Channel Interchange: daily
Figure 1-9. Maintenance-related system parameters screen
MAINTENANCE-RELATED SYSTEM PARAMETERS
Product Identification: 1010101010
Restart Notification? y
Test Remote Access Port? y
CPE Alarm Activation Level: none
Start Time: 23 : 00
Daily Maintenance: daily
SPE Interchange: daily
Figure 1-9
shows the screen with
Page
Abbrev Alarm Report? y
Abbrev Alarm Report? y
Suspension Threshold: 5
Stop Time: 06 : 00
Save Translation: daily
System Clocks Interchange: daily
Issue 2
November 2000
1-22
.
Enter
1 of
3
SPE A