DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN 555-233-121
2
SREPN Maintenance
Maintenance procedure
list fiber-link
FIBER -------- ENDPOINT 1 --------
LINK# TYPE A-PNC DS1
1
sni
2
sni
3
sni
Figure 2-12. List fiber-link screen (SRP)
2. Enter status sys-link UUCSS to obtain status information and the current
or faulted hardware path (the list of hardware components over which the
link travels).
status sys-link 01e20
Location: 01E2001
Current Path: present
Location
01A1
PN 01
01E01
2 A-PNC
01E02
01E20
Figure 2-13. Status sys-link screen (Release 9r)
FIBER LINK ADMINISTRATION
B-PNC DS1
LOC
CONV
LOC
LOC
01A17
01B17
01A18
01B18
01E20 01E21 01D20 01D21
Faulted Path: none
State: up
Maintenance
Name
Alarms
PKT-INT
none
PKT-BUS
none
EXP-INTF
none
FIBER-LK
none
SNI-BD
none
SNI-BD
none
-------- ENDPOINT 2 --------
TYPE A-PNC DS1
CONV
LOC
CONV
LOC
LOC
ei
10E01 10D02
ei
06E01 06D02
ei
22A01 22A02 22B02 22B03 TN574
Type/Chan: INL
Current Hardware Path
Maintenance
Location
Issue 2
November 2000
Page 1 SPE A
B-PNC DS1
DS1
LOC
CONV
CONV
LOC
TYPE
Page
1 of
2
SPE A
Alarms: none
Last Fault:
Name
Alarms
2-19

Advertisement