Avaya DEFINITY Series Installation And Maintenance Manual page 80

Enterprise communications server
Hide thumbs Also See for DEFINITY Series:
Table of Contents

Advertisement

DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN 555-233-121
2
SREPN Maintenance
Fault isolation procedures
To isolate fiber link faults use two procedures:
''Gather information''
''Test the fiber link hardware''
Gather information
1. Know which fiber span to isolate by using the link information (status
health) reports from both the Release 9r and the SREPN and the
information in
2. Enter display alarms and press
3. Type pnc in the Category field, then choose
4. Look for any on-board alarms other than the EI circuit pack. If there are
any, replace the circuit pack. Do not replace the EI circuit pack unless there
are on-board alarms.
If No,
5. Enter display errors and press
6. Type pnc in the Category field, then choose
7. Check for any of the following errors:
8. If you find one or more of the above errors, go to Step 10.
Table 2-7 on page
NOTE:
Since the system is in Survive mode, the Release 9r thinks it has lost
its connections to the EPN. Therefore, alarms may be present, even
though the problem has been diagnosed and fixed.
Maintenance
Error
Object
Type
FIBER-LK
Any
SNI-BD
513
EXP-INTF
257 769
770
1281
1537
3073
3074
3075
3076
3585
3841
3842
2-18.
.
Enter
.
Enter
.
Enter
.
Enter
Issue 2
November 2000
2-26

Advertisement

Table of Contents
loading

Table of Contents