Command
Advanced Configuration (continued)
Resets
NOTE:
The remote power state for HDBT/XTP mode is forced to Off (
unit is not in DTP mode result in an
System reset (soft reset)
Absolute system reset
Absolute system reset, retain
IP settings
Serial Port Configuration
Set serial port parameters
View the serial port
parameters
Set UART start point
View UART start point
Send commands over
RS-232 insertion
KEY:
X3#
= Command length
X5&
= Remote port number
X5*
= Baud rate of port
X5(
= Parity
X6)
= Data bits
X6!
= Stop bits
X6%
= UART port start point
ASCII Command
Response
(Host to Switcher)
(Switcher to Host)
E14
(Not valid for current configuration) error message.
E ZXXX }
Zpx ]
E
}
]
ZQQQ
Zpq
E
}
]
ZY
Zpy
EX5& * X5* , X5( , X6) , X6! CP }
Cpn X5& •Ccp X5* , X5( , X6) , X6!]
EX5& CP }
X5* , X5( , X6) , X6!]
Verbose modes 2 and 3:
Cpn X5& •Ccp X5* , X5( , X6) , X6!]
EX6% MD }
X6%]
Pmd
E MD }
X6%]
E +snds X5& * X3#}
Snds X5&]
command
Number of characters to be sent
1
= Remote port (3-pole captive screw)
4
= Universal asynchronous receiver-transmitter (UART) on TP input 4
(IN1804 DI and DI/DO only)
9
= UART on TP output 1A (IN1804 DO and IN1804 DI/DO only)
300
,
14400
Odd
,
7
8
or
1
(default) or
Start point for UART ports:
TP IN4 =
TP OUT 1A =
Default =
IN1804 Seamless Scaling Switchers • SIS Configuration and Control
Additional Description
0
). Attempts to change the power setting while the
Reset all device settings to factory
defaults.
Set all device settings plus DHCP and
the IP address to factory defaults.
DHCP =
192
This command also removes the
initial serial number password that is
set at the factory and resets it to no
password.
Same as absolute system reset except
that IP address, subnet mask, gateway
address, DHCP, and port mapping are
not reset.
Set the RS-232 port parameters
View port parameters
X6!
Set the port number start point for the
over TP Universal asynchronous receiver-
transmitter (UART).
View the port number start point for the
over TP UART.
Send a command of
port
600
1200
1800
2400
3600
,
,
,
,
19200
28800
38400
57600
,
,
,
,
Even
N
M
S
,
one (default),
ark,
pace (only the first letter is required).
(default)
2
X6%
+ 1 (IN1804 DI and IN1804 DI/DO only)
X6%
+ 3 (IN1804 DO and IN1804 DI/DO only)
2000
Off
, IP address =
168
254
254
.
.
.
.
X5*
X5(
X6)
,
,
X5&
of port
.
X3#
characters from
X5&
to a TP endpoint.
4800, 7200
9600
,
,
(default),
115200
,
, and
77

Advertisement