Pentair FOLEO 5800 XTR Installer Manual page 98

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer Manual Foleo - Troubleshooting
Issue
Improper regeneration.
Incorrect brine setting.
Incorrect hardness or capacity
settings.
Run out of
Water hardness has increased.
conditioned water
between
regenerations.
Restricted meter turbine rotation due
to foreign matter in meter.
Too much water used between the first
cycle of regeneration and brine draw.
Air leak in brine line.
Incorrect BLFC size with regards to
injector size.
BLFC/DLFC causing inconsistent brine
draw clogged with resin or other
Brine tank
debris.
overflow.
Incorrect controller settings.
Injector plugged causing refill instead
of drawing.
98 / 112
Cause
Reset and recovery
Control brine dosage set and repeat
regeneration.
Set brine to proper level.
See 5.4.3. Valve screen, page 54.
Set hardness and capacity settings.
See 5.4.4. Feed Water Hardness (H),
page 42 and 5.5.6. Unit capacity (C),
page 45.
Check hardness settings.
See 5.4.4. Feed Water Hardness (H),
page 42.
Remove meter housing, free up
turbine and flush with clean water.
Turbine should spin freely. If not,
replace meter.
Set regeneration times at low or no
water usage.
See 5.4.4. Regeneration screen,
page 56.
Eventually installing the optional
®
Pentair
fast brine valve will be
necessary. Contact your supplier.
Check all connections in brine line for
any leaks.
Use of too small BLFC with large
injector will reduce draw rates.
Clean BLFC & DLFC.
Check that controller setting match
with your actual softener model and/or
valve configuration.
Clean injector.
See 8.5.4. Injector and injector screen
cleaning, page 80