Recommendations; Use Original Spare Parts; Use Original Approved Lubricants; Cleaning And Maintenance - Pentair FOLEO 5800 XTR Installer Manual

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer Manual Foleo - Maintenance
8.4.

Recommendations

8.4.1. Use original spare parts

CAUTION
To ensure correct operation and safety of the device, only use original spare parts and
accessories recommended by the manufacturer.
Parts to keep in stock for potential replacements are motor and optical sensor, controller,
transformer, injectors, flapper kit, o-ring kit, refill controller and DLFC.

8.4.2. Use original approved lubricants

®
P-80
Emulsion lubricant.
8.5.

Cleaning and maintenance

8.5.1. First steps

Before any cleaning or maintenance procedure, complete the following step:
No.
CAUTION
These operations must be performed before any cleaning or maintenance procedure.
A
Shut off water supply or put bypass valve(s) into bypass position.
Relieve system pressure before performing any operations by cycling the valve in all
B
regeneration phases while the main water line is shut off.
C
Unplug the wall-mounted transformer.
76 / 112
Operation
Ref. MKT-IM-038 / C - 15.11.2019