Installer Manual Foleo - Maintenance
8.5.7.3 BLFC cleaning
No.
Remove the softener cover, see 8.5.1. First steps, page 76 and 8.5.2. Softener cover
A
removal, page 77.
B
Disconnect the tube (14) (push fit system (13)).
C
Unscrew the BLFC holder (12) from chlorine generator (8).
D
Using pliers, remove the grid (10) from BLFC holder (12).
E
Remove the BLFC (11) from the grid (10).
F
Clean or change the BLFC (11).
G
Lubricate the seal (9) with approved P-80
CAUTION
Using another type of lubricant, such as petroleum-based lubricants (Vaseline, oils, or
hydrocarbon-based lubricants) or silicone grease, may damage the valve.
H
Reverse above procedure steps to rebuild.
8.5.7.4 Chlorine generator cleaning/replacement
No.
Remove the softener cover, see 8.5.1. First steps, page 76 and 8.5.2. Softener cover
A
removal, page 77.
B
Disconnect the tube (14) (push fit system (13)).
C
Unscrew the BLFC holder (12) from chlorine generator (8).
Remove the nut (6), washer (5), o-ring (4) and chlorine generator (8) with its elbow (3)
D
from support (1).
E
Unscrew the chlorine generator (8) from its elbow (3).
F
Clean or replace the chlorine generator (8).
G
Lubricate the seals (2+4+7+9) with approved P-80
CAUTION
Using another type of lubricant, such as petroleum-based lubricants (Vaseline, oils, or
hydrocarbon-based lubricants) or silicone grease, may damage the valve.
H
Reverse above procedure steps to rebuild.
CAUTION
To avoid any damage, the chlorine generator (8) must be installed horizontally or slightly
inclined downwards, as shown in the following illustration.
CAUTION
The controller must be set with chlorine generator, see 5.4.10. Chlorine generation
screen, page 62.
86 / 112
Operation
®
Emulsion lubricant only.
Operation
®
Emulsion lubricant only.
Ref. MKT-IM-038 / C - 15.11.2019