Compressor Usage And Electrical Data For Standard Units - Carrier AquaSnap Touch Pilot Junior Series Installation, Operation And Maintenance Instructions

Reversible air-to-water heat pumps
Table of Contents

Advertisement

9 - ELECTRICAL DATA, 30RQS AND 30RQSY UNITS
Motors of single and dual high-pressure pumps (OPTION 116R, 116S, 116V, 116W)
No.
Description
(2)
(3)
1
Nominal efficiency at full load and nominal voltage
1
Nominal efficiency at 75% rated load and nominal voltage
1
Nominal efficiency at 50% rated load and nominal voltage
2
Efficiency level
3
Year of manufacture
Manufacturer's name and trademark, commercial 
4
registration number and place of manufacturer
5
Product's model number
6
Number of motor poles
Rated shaft power output at full load and nominal voltage 
7-1
(400 V)
7-2 Maximum power input (400 V)
8
Rated input frequency 
9-1 Rated voltage
9-2 Maximum current drawn (400 V)†
10 Rated speed
11
Product disassembly, recycling or disposal at end of life 
12 Operating conditions for which the motor is specifically designed
I 
- Altitudes above sea level
II  
- Ambient air temperature
IV  
- Maximum air temperature
V  
- Potentially explosive atmospheres
(1)  Required by regulation 640/2009 with regard to the application of directive 2009/125/EC on the eco-design requirements for electric motors
(2)  Item number imposed by regulation 640/2009, annex I2b.
(3)  Description given by regulation 640/2009, annex I2b.
(4)  To obtain the maximum power input for a unit with hydraulic module add the maximum unit power input from the electrical data table to the pump power input.
† 
To obtain the maximum unit operating current draw for a unit with hydraulic module add the maximum unit current draw from the electrical data table to the pump current 
draw.
††  Above 1000 m, a degradation of 3% for each 500 m should be taken into consideration.

9.3 - Compressor usage and electrical data for standard units

I Max
Compressor
I Nom
(Un)
ZP90
11.4
16
ZP103
13.1
21
ZP120
15.1
22
ZP137
16.6
25
ZP154
18.7
31
ZP182
23.9
34
Total circuit A
Total circuit B
I Nom  
Nominal current draw at Eurovent conditions (see definition of conditions under nominal unit current draw), A
I Max  
Maximum operating current at 360 V, A
(1)
Locked rotor current at nominal voltage, A
(2)
Locked rotor current at nominal voltage, electronic starter
28
(4)
I Max
LRA
LRA
Cosine
(1)
(2)
(Un-
A
A
phi max.
10%)
17.6
95
57
23.1
111
67
24.3
118
71
27.8
118
71
34.9
140
84
37.3
174
104
039
045
050
060
%
84,8 84,8 84,8 84,8 84,8 84,8 84,8 84,8 84,8 85,9 85,9 85,9
%
82,2 82,2 82,2 82,2 82,2 82,2 82,2 82,2 82,2
%
79
79
79
79
This information varies depending on the manufacturer and model at the 
time of incorporation. Please refer to the motor name plates.
2
2
2
2
kW
1,7
1,7
1,7
1,7
kW
2,4
2,4
2,4
2,4
Hz
50
50
50
50
V
A
4,2
4,2
4,2
4,2
rpm
2870 2870 2870 2870 2870 2870 2870 2870 2870 2855 2855 2855
r/s
48
48
48
48
Disassembly using standard tools. Disposal and recycling using an 
m
°C
Please refer to the operating conditions given in this manual or in the 
°C
specific conditions in the Carrier selection programs.
Circuit
039 045 050 060 070 078 080 090 100 120 140 160
A
2
-
0.82
B
-
-
A
-
2
0.84
B
-
-
A
-
-
2
0.84
B
-
-
A
-
-
0.86
B
-
-
A
-
-
0.85
B
-
-
A
-
-
0.84
B
-
-
2
2
2
-
-
30RQS/RQSY
070
078
080
090
100
79
79
79
79
79
IE3
2
2
2
2
2
1,7
1,7
1,7
1,7
1,7
2,4
2,4
2,4
2,4
2,4
50
50
50
50
50
3 x 400 
4,2
4,2
4,2
4,2
4,2
48
48
48
48
48
appropriate company.
< 1000††
< 55
Non-ATEX environment
30RQS/30RQSY
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
-
-
-
3
-
-
-
-
-
-
-
-
2
-
-
-
-
-
-
-
-
-
-
-
-
2
2
-
-
-
-
-
-
-
2
2
2
2
3
-
-
-
-
-
-
120
140
160
84
84
84
82,1 82,1 82,1
2
2
2
2,2
2,2
2,2
2,9
2,9
2,9
50
50
50
5
5
5
48
48
48
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3
-
2
-
-
-
2
-
-
3
-
2
-
-
-
2
3
3
2
2
-
-
2
2

Advertisement