Water Evaporator/Condenser; Refrigerant; High-Pressure Safety Switch; Storage Tank - Carrier AquaSnap Touch Pilot Junior Series Installation, Operation And Maintenance Instructions

Reversible air-to-water heat pumps
Table of Contents

Advertisement

15 - MAJOR SYSTEM COMPONENTS
According  to  the  Regulation  No.  640/2009  and  amendment  4/2014  implementing  Directive  2005/32/EC  with  regard  to 
ecodesign requirements for electric motors.
Product/option
Motor type
Number of poles
Nominal input frequency
Nominal voltage
Number of phases
Motor included in the application domain of the regulation 
640/2009 and amendment 4/2014
Sales leaflet for exemption
Ambient air temperature for which the motor is 
specifically designed
(1)  Only for sizes 039-050 and 080-120
(2)  Only for sizes 060-078 and 140-160

15.8 - Water evaporator/condenser

The evaporator/condenser is a plate heat exchanger with one or 
two refrigerant circuits. The water connection of the heat exchanger 
is a Victaulic connection. It has a thermal insulation of 19 mm thick 
polyurethane foam and includes frost protection, as standard.
The  products  that  may  be  added  for  thermal  insulation  of  the 
containers during the water piping connection procedure must be 
chemically neutral in relation to the materials and coatings to which 
they are applied. This is also the case for the products originally 
supplied by Carrier SCS.
NOTES - Monitoring during operation:
• Follow the regulations on monitoring pressurised
equipment.
• It is normally required that the user or operator sets up
and maintains a monitoring and maintenance file.
• If there are no regulations or to complement them follow
the control programmes of EN 378.
• If they exist follow local professional recommendations.
• Regularly check for possible presence of impurities
(e.g. silica grains) in the heat exchange fluids. These
impurities maybe the cause of the wear or corrosion
by puncture.
• The reports of periodical checks by the user or operator
must be included in the supervision and maintenance
file.
30RQS standard
(1)
or
with option 15LS
Dual-speed
asynchronous
8
Hz
50
V
400
3
No
Article 2.1
°C
68.5

15.9 - Refrigerant

30RQS/RQSY units operate with refrigerant R-410A.

15.10 - High-pressure safety switch

30RQS/RQSY units are equipped with automatically reset safety 
pressure  switches  on  the  high-pressure  side.  For  the  alarm 
acknowledgements refer to the 30RB/RQ Touch Pilot Junior control 
manual).

15.11 - Storage tank

30RQS/RQSY  units  are  equipped  with  mechanically  welded 
storage tanks that permit storing the excess charge when the unit 
operates in heating mode. 

15.12 - Four-way valve

This  permits  reversal  of  the  cycle  for  operation  in  cooling  and 
heating mode and during defrost cycles.

15.13 - Control box

The control box of the 30rqs/rqsy units is equipped with electric 
heaters to prevent condensation during operation at low outside 
temperatures. they are installed on the top of the control box on 
the outside, and are covered by a thermal insulation layer. these 
heaters are switched on, based on the outside temperature.
30RQSY standard or
30RQS standard
30RQS standard with
(2)
Dual-speed
Asynchronous
asynchronous
6
50
400
3
No
Article 2.1
68.5
option 42
6
60
400
3
No
Article 2.1
68.5
45