5. Click the Login button.
The System Information page displays.
6. Select Maintenance > Troubleshooting > Traceroute IPv4.
7. In the IP Address/Hostname field, enter the IP address or host name of the device for
which the path must be discovered.
8. In the Probes Per Hop field, enter the number of probes per hop.
The default value is 3. The range is 1 to 10.
9. In the Max TTL field, enter the maximum time to live (TTL) for the destination.
The default value is 30. The range is 1 to 255.
10. In the Init TTL field, enter the initial TTL to be used.
The default value is 1. The range is 1 to 255.
11. In the MaxFail field, enter the maximum number of failures allowed in the session.
The default value is 5. The range is 1 to 255.
12. In the Interval (secs) field, enter the time between probes in seconds.
The default value is 3. The range is 1 to 60.
13. In the Port field, enter the UDP destination port for the probe packets.