CAUTION:
as are the V– terminals. The same polarity terminal can be wired together from the same
source to provide an additional current path in a higher power chassis. Do not connect
the terminals to different sources.
Table 10 on page 38
describes the LEDs on the DC power supply modules.
Table 10: DC Power Supply Module LEDs
Label
Color
IN (Input)
Unlit
Green
OUT (Output)
Unlit
Green
! (Fault)
Amber
SEE ALSO
Routine Maintenance Procedures for MX204 Routers | 115
Maintaining the MX204 Power Supplies | 126

MX204 Router AC Power Specifications

Table 11 on page 39
lists the AC power system electrical specifications.
On the DC power supply, the V+ terminals are shunted internally together,
State
Off
On steadily
Off
On steadily
On steadily
Description
The power supply is disconnected from power
source, or the power supply is not receiving
power.
Power supply is receiving power.
Power supply output is off.
The power supply is sending out power
correctly.
An error has been detected in the power
supply. Replace the power supply as soon as
possible. To maintain proper airflow through
the chassis, leave the power supply installed
in the chassis until you are ready to replace
it.