Juniper MX204 Hardware Manual page 124

Universal routing platform
Hide thumbs Also See for MX204:
Table of Contents

Advertisement

FPC 0 EA0 Chip
FPC 0 EA0-XR0 Chip
FPC 0 EA0-XR1 Chip
Power PEM 0
PEM 1
Fans
Fan Tray 0 Fan 0
Fan Tray 0 Fan 1
Fan Tray 1 Fan 0
Fan Tray 1 Fan 1
Fan Tray 2 Fan 0
Fan Tray 2 Fan 1
Make sure that the power and grounding cables are arranged so that they do not obstruct access to
other router components.
Routinely check the status LEDs on the power supply faceplates and the craft interface to determine if
the power supplies are functioning normally.
Check the red and yellow alarm LEDs on the craft interface. Power supply failure or removal triggers an
alarm that causes one or both of the LEDs to light. You can display the associated error messages by
issuing the following command:
user@host> show chassis alarms
Periodically inspect the site to ensure that the grounding and power cables connected to the router are
securely in place and that there is no moisture accumulating near the router.
CAUTION:
SEE ALSO
MX204 Power System Description | 33
MX204 Power Supply Module LEDs | 35
Do not mix AC and DC power supplies in the same chassis.