Maintaining Mx204 Power System Components; Maintaining The Mx204 Power Supplies - Juniper MX204 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX204:
Table of Contents

Advertisement

Maintaining MX204 Power System Components

IN THIS SECTION

Maintaining the MX204 Power Supplies | 126

Replacing an MX204 AC Power Supply | 128
Replacing an MX204 DC Power Supply | 130
Maintaining the MX204 Power Supplies
Purpose
For optimum router performance, verify the condition of the power supply modules.
Action
On a regular basis, check the power supply status:
To check the power supply status, issue the show chassis environment CLI command. The output is
similar to the following:
user@host> show chassis environment
Class Item
Temp
CB 0 Top Right Inlet Sensor
CB 0 Top Left Inlet Sensor
CB 0 Top Right Exhaust Sensor
CB 0 Top Left Exhaust Sensor
CB 0 CPU Core-0 Temp
CB 0 CPU Core-1 Temp
CB 0 CPU Core-2 Temp
CB 0 CPU Core-3 Temp
CB 0 CPU Core-4 Temp
CB 0 CPU Core-5 Temp
CB 0 CPU Core-6 Temp
CB 0 CPU Core-7 Temp
FPC 0 EA0_HMC0 Logic die
FPC 0 EA0_HMC0 DRAM botm
FPC 0 EA0_HMC1 Logic die
FPC 0 EA0_HMC1 DRAM botm
Status
Measurement
OK
26 degrees C / 78 degrees F
OK
22 degrees C / 71 degrees F
OK
31 degrees C / 87 degrees F
OK
44 degrees C / 111 degrees F
OK
35 degrees C / 95 degrees F
OK
34 degrees C / 93 degrees F
OK
34 degrees C / 93 degrees F
OK
34 degrees C / 93 degrees F
OK
33 degrees C / 91 degrees F
OK
33 degrees C / 91 degrees F
OK
33 degrees C / 91 degrees F
OK
33 degrees C / 91 degrees F
OK
55 degrees C / 131 degrees F
OK
52 degrees C / 125 degrees F
OK
55 degrees C / 131 degrees F
OK
52 degrees C / 125 degrees F