6.9.7 FUSING PRESSURE ADJUSTMENT

[A]
1. Make a black copy (sky shot, A3/Double Letter paper).
2. As soon as the paper starts to exit, open the left door to stop the paper in the
fusing unit.
3. Wait about 20 seconds, then turn the fusing knob quickly to deliver the paper.
4. Measure the nip band width [A] at the center.
5. If the nip band width is not within 8.8 ± 0.5 mm, change the spring hook
position [B].