3.9.5.3 Meter door and cleanout door latches

The tension on the cleanout door latches (1) and
the meter door latches (2) can be adjusted to
increase or decrease the preload on the cleanout
door and the meter door. If the preload is too
small, the doors will not seal correctly. If the
tension is too tight, the latches will be difficult to
close.
The tension can be adjusted by opening each latch
and turning the two stop-nuts evenly in or out.
Make sure the door preload is enough before
putting the unit back into service.

3.9.5.4 Meter door tray

The tray (1) on the meter door can be adjusted
vertically in order to increase or decrease the
tension between the rubber seal on the tray and
the meter roll.
To adjust the meter door tray:
1. Loosen the two nuts (2) holding the tray to the
meter door.
2. Move the tray to the desired position.
3. Tighten the nuts to lock the tray into position.