Adjusting The Cup Heater Temperature; Programming Of Energy Saving Time And Groups Stand-By - Wega Wegaconcept Use And Maintenance Manual

Table of Contents

Advertisement

Wegaconcept
28.7

Adjusting the cup heater temperature

To modify the cup heater temperature, proceed as
follows:
ENTER
Hold down the ENTER button for at least 5 seconds.
(x 5 secs.)
Scroll the menu until the item is highlighted
01 SERV. BOILER PRESS
02 COFFEE WATER TEMP.
03 GROUPS TEMPERAT.
04 CUP HEATER TEMP.
ENTER
Confirm to access the menu
CUP HEATER
Modify the parameter: increase or decrease
ENTER
Confirm to exit the menu.
01 SERV. BOILER PRESS
02 COFFEE WATER TEMP.
03 GROUPS TEMPERAT.
04 CUP HEATER TEMP.
To exit the programming menu
X
Cup heater temperature(70 ÷ 114 °C).
If a temperature above 114°C is set, the indication
i
CUP HEATER ON will appear on the display and
the cup heater will be activated in continuous
operation.
If setting a temperature below 70°C, the indication
"CUP HEATER--" will appear on the display and the
i
cup heater will be deactivated. Deactivation of
the cup heater by a technician does not allow the
user to activate the cup heater. Deactivation of the
cup heater by the user can be reversed at any time.
42
X °C
28.8
Programming of Energy Saving time
and groups stand-by.
To program the machine (Energy Saving) and groups
(stand-by) start-up and operating times at reduced
temperature, proceed as follows.
Setting the machine START-UP TIME:
ENTER
Hold down the ENTER button for at least 5 seconds.
(x 5 secs.)
Scroll the menu until the item is highlighted
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE
ENTER
Confirm to access the menu
Machine start-up time
Set the time for the machine to start. To switch from
hours (HR) to minutes (MN) press the ( ) key.
Once the minutes (MN) are set, press the ( ) key to
move to the next display.
Time of the first stand-by period of the delivery groups:
STANDBY 1 TIME
FROM HR:MN
Set the start time for stand-by. To switch from hours
(HR) to minutes (MN) press the ( ) key.
Once the minutes (MN) are set, press ( ).
STANDBY 1 TIME
Set the end time for stand-by. To switch from hours
(HR) to minutes (MN) press the ( ) key.
Once the minutes (MN) are set, press ( ).
You can now program the time for the second stand-by
period.
ON TIME
HH:MM
TO HR:MN
Technical manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents