Wega Wegaconcept Use And Maintenance Manual page 36

Table of Contents

Advertisement

Wegaconcept
ALARM
AUTOSTEAMER SENSOR
STEAM BOILER HEATING
TIMEOUT
HEATING TIMEOUT GROUP ON
GROUP #
HEATING OUT OF SERVICE
GROUP ON GROUP #
COFFEE WATER HEATING
TIMEOUT ON GROUP #
COFFEE WATER HEATING OUT OF
SERVICE ON GROUP #
FILLING TIMEOUT
FILLING TIMEOUT
SAFETY LEVEL
COFFEE WATER PRESSURE ON
GROUP #
VOLUMETRIC DOSING DEVICE
36
CAUSE
Autosteamer temperature probe disconnected.
Autosteamer probe in short circuit.
Autosteamer probe overheating.
Service boiler heating circuit disconnected.
Heating element protection thermostat open.
Fuse F7 burned.
Heating circuit group on group disconnected.
Group heating element interrupted.
Safety thermostat open.
Fuse(s) F6- F5 burned.
Heating circuit group on group disconnected.
Group heating element interrupted
Safety thermostat open.
Fuse(s) F6- F5 burned.
Water boiler heating circuit on group disconnected.
Group water boiler heating element interrupted.
Safety thermostat open.
Fuse(s) F2 - F3 - F8 - F9 burned.
Water boiler heating circuit on group disconnected.
Group water boiler heating element interrupted.
Safety thermostat open.
Fuse(s) F2 - F3 - F8 - F9 burned.
FIRST INSTALLATION.
The service boiler has not completed the filling
within the maximum time (255 seconds).
The level probe does not detect the presence of
water.
IN OPERATION.
The service boiler has not completed the filling
within the maximum time (90 seconds).
The water in the service boiler has dropped below the
minimum level.
The service boiler has not reached the filling pressure
within the maximum time (60 seconds).
The volumetric dosing device does not perform water
count.
SOLUTION
Check for proper connection of the autosteamer probe and
replace it if necessary.
Check steam boiler heating circuit and replace burned compo-
nents if necessary.
Check heating circuit group : Group heating element; Safety
thermostat, related fuse and triac in the control unit; main
switch; phase connection for 380 V version.
if necessary replace the defective components.
Check heating circuit group : Group heating element; Safety
thermostat, related fuse and triac in the control unit; main
switch; phase connection for 380 V version.
if necessary replace the defective components.
Check water boiler heating on group: heating element; safety
thermostat, related fuse and triac in the control unit; main
switch; phase connection for 380 V version.
if necessary replace the defective components.
Check water boiler heating on group: heating element; safety
thermostat, related fuse and triac in the control unit; main
switch; phase connection for 380 V version.
if necessary replace the defective components.
Check hydraulic circuit for service boiler water filling:
Check that there is actually water in the mains water supply.
Check filling solenoid valve / pump filter
Check fuse F3 on control unit.
Check hydraulic circuit for service boiler water filling:
Check that there is actually water in the mains water supply.
Check filling solenoid valve / pump filter
Check fuse F3 on control unit.
Check for correct connection of the minimum level probe.
Check coffee boiler hydraulic circuit:
Check that there is actually water in the mains water supply.
Check solenoid valve / pump filter.
Check volumetric dosing device (filter input / 0.5mm gigler
output).
Check the volumetric dosing device connection.
Check that there is actually water in the mains water supply.
Check pump filter / volumetric dosing device filter.
Check 1 mm group gigler.
Check 0.5 mm volumetric dosing device gigler.