Wega Wegaconcept Use And Maintenance Manual page 61

Table of Contents

Advertisement

Fuse
F1
Fuse 5x20 delayed by 6.3A
F2
Fuse 5x20 delayed by 12.5A
F3
Fuse 5x20 delayed by 12.5A
F4
Fuse 5x20 delayed by 1A
F5
Fuse 5x20 delayed by 10A
F6
Fuse 5x20 delayed by 10A
F7
Fuse 5x20 delayed by 1A
F8
Fuse 5x20 delayed by 12.5A
F9
Fuse 5x20 delayed by 12.5A
Off On SW1 Switch
1
Not used. Leave on OFF mode.
2
Exclude the double doses
3
Reserve
4
Reserve.
5
Reserve.
6
ON = rinse active for 3 secs. PROG./STOP key.
ON = excludes the automatic control of the services boiler
7
temperature.
8
ON = Pre-infusion active
LED
Description
DL1
Cup heater
DL2
+5V
DL3
+9V
DL4
Heating element control boiler group 4
DL5
Heating element control boiler group 2
DL6
Heating element control boiler group 3
DL7
Heating element control boiler group 1
DL8
group 1 heating element
DL9
+5V
DL10
+9VB
DL11
group 3 heating element
DL12
+9VA
DL13
group 2 heating element
DL14
group 4 heating element
DL15
group 4 volumetric counter
DL16
group 3 volumetric counter
DL17
group 2 volumetric counter
DL18
group 1 volumetric counter
DL19
services 1 boiler heating element
DL20
+12V pressure gauge
DL21
services 2 boiler heating element
+VAL-T transducer's power supply to +VAL
+5V-T
transducer's power supply to +5V
Technical manual
Description
Protects: from RL1 to RL14
It protects: coffee boiler heating elements group 2
It protects: coffee boiler heating elements group 1
Protects: transformer's double winding
Protects : group heating elements 1 and 3
Protects : group heating elements 2 and 4
Protects: services boiler heating elements 1 and 2
It protects: coffee boiler heating elements group 3
It protects: coffee boiler heating elements group 4
Off On SW2 Switch
9
ON = 6 doses keyboard.
10
ON = rinse active for 3 secs. dose keys
11
ON = Active Credit / Debit.
12
ON = Reset machine life cycle
13
ON = Continuous disabled.
14
ON = NTC probe
15
ON = Serial communication active.
ON = MICRO-Processor programming.
16
OFF = Machine service enabled
Jumper Description
JP2
Not managed
JP4
Aux
JP13
TX-RX signal inversion
JP19
TX-RX signal inversion
Relay
Description
RL1
Pump
RL2
Solenoid valve group 1
RL3
Solenoid valve group 3
RL4
Solenoid valve group 2
RL5
Solenoid valve group 4
RL6
Boiler filling solenoid valve
RL7
Hot water mix solenoid valve
RL8
Tea solenoid valve
RL9
Autosteamer steam solenoid valve
RL10
Cup heater
RL11
Aux. solenoid valve
RL12
Air solenoid valve
RL13
Tea solenoid valve 2
RL14
Aux
Wegaconcept