1. INITIAL SETTING AND ADJUSTMENT
[Equipment ID]
[Details]
13. Repeat the procedures from step 4 to enter the settings to another processor unit.
14. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
1.4.3
Activating the connection with the processor unit of the FAR-
2xx8 series radar
1. Click [Radar] on the menu bar.
2. Check the check box for each FAR-2xx8 series radar processor unit to be con-
nected. Setting range: [RAD111] to [RAD114]
The Equipment ID checked on this step is shown on the menu bar.
Note: Do not use [RAD001] to [RAD010].
1-22
Item
Select the Equipment ID from the pull-down list.
The pull-down list options change according to the setting at
[Sensor Setting].
• [Name]: Enter the appropriate
sensor name.
• [Data Type]: Set the contact
output. [Normally Open] is for
[Channel 01] to [Channel 02],
[Normally Closed] is for
[Channel 03] to [Channel 04].
Note: [Data Type] is not
shown for the sensor adapter
setting.
• [Output Time (100msec)]: Set
the output time (recommend-
ed value: 10).
• [Dead Band (100msec)]: Set the dead band after output (rec-
ommended value: 5).
• [Calibration Active]: Keep the default setting. (Default: without
check)
• [Active Status (1)], [Active Status (0)]: Keep the default set-
ting.
RAD001 through RAD010 are not used.
Remarks