General technical specifications
General technical specifications for SIMOTION P320-4
Article numbers
Dimensions
Weight
Supply voltage (DC)
Short-term voltage interruption in accord‐
ance with Namur
Max. power consumption
Degree of protection
Protection class
Safety regulations
Noise emission
Quality assurance
The upstream power supply must generate a safety extra-low voltage with safe electrical
1
isolation according to IEC 60364-4-41 or an NEC Class 2 SELV and LPS according to IEC/
UL/EN/ DIN-EN 60950-1 (see the section "Connecting the power supply (24 V DC)
(Page 121)").
Electromagnetic compatibility
Electromagnetic compatibility
Interference emission
Immunity with regard to conducted
interference on the supply lines
Noise immunity on signal lines
Immunity to electrostatic discharge ± 6 kV contact discharge according to IEC 61000-4-2
Immunity to RF interference
Immunity to magnetic fields
134
SIMOTION P320-4 E
● 6AU1320-4DE65-3AF0
SIMOTION P320-4 S
● 6AU1320-4DS66-3AG0
262 × 133 × 50.5 (W × H × D in mm)
Approximately 2 kg
24 VDC
1
Min. 15 ms (at 20.4 V)
Max. 10 events/h; recovery time min. 1 s
64.8 W (at 24 V)
IP 20 according to IEC 60529
Protection class I according to IEC 61140
EN 60950-1; UL 60950-1; UL 508;
<40dB (A) to DIN 45635-1
In accordance with ISO 9001
EN 61000-6-3, EN 61000-6-4, CISPR220 class B; FCC class A
± 2 kV according to IEC 61000-4-4; burst
± 1 kV according to IEC 61000-4-5; symmetrical surge
± 2 kV according to IEC 61000-4-5; asymmetrical surge
± 1 kV according to IEC 61000-4-4; burst; length < 3 m
± 2 kV according to IEC 61000-4-4; burst; length > 3 m
± 2 kV according to IEC 61000-4-5; surge; length > 30 m
± 8 kV air discharge according to IEC 61000-4-2
10 V/m 80–1000 MHz and 1.4–2 GHz, 80% AM according to
IEC 61000-4-3
1 V/m 2–2.7 GHz, 80% AM according to IEC 61000-4-3
10 V 10 kHz to 80 MHz, 80% AM according to IEC 61000-4-6
100 A/m, 50/60 Hz according to IEC 61000-4-8
(-20%/+20%)