2
If the catch (1) securing the circulation pump to the screw accidentally
breaks.
Secure the pump to the screw and secure the latter using a screw,
screwing the latter into the slot (2).
Size of the screw 3.5x19 Code 5024 79 51- 00/2
1
When reassembling, make sure the seal is in its seat in order to avoid
water leaks.

16.4.2 Front counterweight

Remove the worktop (see relevant paragraph).
Remove the control panel (see relevant paragraph).
Remove the iron ring securing the bellow seal to the front panel.
Unfasten the screws securing the door safety interlock (see related paragraph).
Remove the front panel (see relevant paragraph).
Pull out the Jet pipe (see related paragraph).
Pull out the lamp from its seat.
Unfasten the five screws securing the front counterweight to the welded tub
assembly.
When tightening the screws, take care:
If the welded tub assembly is new, tighten the screws at a torque of 15 Nm.
If the welded tub assembly is not new, align with the existing thread and
tighten the screws at a torque of 10÷12 Nm.
16.4.3 Shock absorber with/without weight sensor
Remove the worktop (see relevant paragraph).
Remove the control panel (see relevant paragraph).
Remove the iron ring securing the bellow seal to the front panel.
Unfasten the screws securing the door safety interlock (see related paragraph).
Remove the front panel (see relevant paragraph).
Remove the circulation pump with the screw (see related paragraph).
Remove the connector if the shock absorber is fitted with a weight sensor.
Pull out the pins securing it to the tub and crosspiece.
To reposition the pins, see para. 16.4.7 on page 92.