Alarm
Alarm Description
Code
E5A
FCV Heating
E5H
FCV Under Voltage
E5C
FCV Over Voltage
E5D
FCV Unknown Message
E5E
FCV-MB Communication
E5F
FCV Fault
Insufficient heating during
E61
washing cycle
Overheating during washing
E62
cycle
E66
Heater or drying relay failure
E68
Ground current leakage
Washing heating
E69
element opened
E6A
Heating relay sensing failure
E71
Washing NTC failure
E72
Output drying NTC failure
Technical Support - DMM
Fault Condition
High temperature on Heat
Sink (>88°C) or NTC of
Over load condition, Motor Control board defective
FCV board open
Dc bus voltage bellow the
FCV mains wiring Motor Control board defective
allowed value (175V)
Dc bus voltage above the
Motor Control board defective
allowed value (430V)
Power line voltage too high
Transmission line noisy /
Message received by FCV
FCV defective
is not correct
MB defective
Communication wiring problems
Wiring defective
Protocol communication
FCV defective, WD defective,
between FCV and MB not
UI defective
aligned
MB defective, Weight defective
FCV control board is
FCV control board defective or communication wiring problems
continuously in reset
or main board defective
Washing NTC defective
Washing heating timeout
Washing heater element defective
expired
Wiring or main board defective
Water temperature higher
Washing NTC defective
than 88°C for a time longer
Wash heater element defective
than 5 minutes
Wiring or main board defective
Incongruence between
Main board defective
heater relay sensing and
Current leakage between
relay status
Wash/drying heater element and earth
Voltage value on heater
Current leakage between
sensing (wash or dry)
wash or dry heater element and earth
different from Vmains value
Voltage value different from
Wash heating element faulty
Vmains value when heating
(thermo fuses opened)
element is not powered
Wiring defective
during the cycle execution
Main board defective
Wrong input signal to
Main board defective
microprocessor
Wrong input signal to
microprocessor
Washing NTC defective
(open circuit or short
Wiring or main board defective
circuit)
Voltage value out of limit
Output drying NTC defective
(open circuit or short
Wiring or WD board defective
circuit)
Possible Fault
70/106
Machine Action/Status
Reset Key
Cycle blocked after 5 trials
ON/OFF
with door locked
RESET
Cycle blocked after 5 trials
ON/OFF
with door locked
RESET
Cycle blocked after 5 trials
ON/OFF
with door locked
RESET
ON/OFF
---
RESET
ON/OFF
Cycle blocked after 5 trials
RESET
Cycle blocked after 5 trials
ON/OFF
with door unlocked
RESET
START
Heating phases skipped
RESET
Safety Drain cycle
Cycle stopped
RESET
with door unlocked
Safety load cycle.
ON/OFF
Stop of the cycle
RESET
with door locked
Cycle blocked with door
START
opened
RESET
START
No actions
ON/OFF
RESET
Cycle blocked with door
RESET
locked
START
Heating phases skipped
RESET
Drying heating phases
START
skipped
RESET