Parameter group Photovoltaics

7E21 Raise set DHW cylinder temperature PV

Raising the set cylinder temperature for DHW heating
in the case of on-site power consumption.
Requirements: "Enable own energy consumption
for DHW heating 7E11" is set to "1".
7E22 Raise set heating water buffer cylinder temp PV
Raising the set buffer temperature for central heating
when utilising power generated on site.
Requirements: "Enable own energy consumptn for
heating water buffer cyl. 7E12" is set to "1".
7E23 Raise set room temperature PV
Raising the set room temperature for central heating in
the case of on-site power consumption.
Requirements: "Enable own energy consumption
for heating 7E13" is set to "1".
7E25 Reduce set room temperature PV
Lowering the set room temperature for central cooling
in conjunction with utilisation of power generated on
site.
Requirement: "Enable own energy consumption for
cooling 7E15" set to "1".
7E26 Reduce set coolant buffer cylinder temperature PV
Reduction of set room temperature for cooling the
heating water/coolant buffer cylinder when utilising
power generated on site.
Requirement: "Enable own energy consumptn for
coolant buffer cylinder 7E16" set to "1".
270
Setting 1
0.1 K
Setting 1
0.1 K
Setting 1
0.1 K
Note
Applicable for cooling via a heating/cooling circuit or
the separate cooling circuit.
Setting 1
0.1 K
Setting 1
0.1 K