Vitodens 200-w, b2ha
models 45 to 150
wall-mounted, gas-fired condensing boiler in conjunction
with the vitotronic 300-k mw2c cascade control
for operation with natural gas and liquid propane gas
heating input 55 to 530 mbh
16 to 150 kw
read and s (20 pages)
Vitodens 200, programming unit with vitotronic 200, h01 on-board control (2 pages)
Summary of Contents for Viessmann VITOTRONIC 200
Page 1
VIESMANN Operating instructions for the system user Heat pump control unit demo model Vitotronic 200, type WO1B VITOTRONIC 200 Please keep safe. 5600 286 GB 2/2011...
Page 2
Safety instructions For your safety Please follow these safety instructions closely to prevent accidents and mate- rial losses. Safety instructions explained Danger Incorrect work on the system can Danger lead to life-threatening acci- This symbol warns against the dents. risk of injury. Work on electrical equipment must only be carried out by a Please note...
Safety instructions For your safety (cont.) Auxiliary components, spare and wearing parts Please note Components that are not tested with the system may cause sys- tem damage, or may affect its functions. Installation or replacement work must only be carried out by quali- fied personnel.
Page 4
Introductory information Device description The demo model of heat pump control ■ External heat source for central heat- unit Vitotronic 200, type WO1B, can be ing and DHW heating (dual operating used to simulate the operation of the fol- mode) lowing heating systems with heat ■...
Introductory information The control unit is preset at the factory Names of the heating circuits Note ■ "HC1": "Apartment 1" The names of the heating circuits have ■ "HC2": "Apartment 2" only been adapted in "German". In other ■ "HC3": "Apartment 3" languages, the standard designations ■...
Operation Commissioning After switching on the appliance, carry "Yes" The commissioning wizard out the following steps in order: takes you through the required 1. Language setting steps for commissioning the "German" is the default setting. simulated heating system. 2. Date and time settings. "No"...
Operation Control (cont.) Generating a fault message Hold down the OK button. The message "18 Outside temp. sensor" is dis- played.
Page 8
Appendix Menu overview Extended menu Heating/cooling Settings HC1/HC2/HC3/SKK Set DHW temperature Time / Date Party mode Language Economy mode 1 x DHW heating Contrast Set room temperature Time program DHW Brightness Time prog. DHW circ. Temperature unit Set red. room DHW with electr.heating temp Name for...
Appendix Menu overview (cont.) Extended menu — Information Heating/cooling Information Settings System Heating circuit 1 Operating program Outside temperature Heating circuit 2 Time program heating Common flow temp. Heating circuit 3 Time prog.htg/cooling Operating status system Cooling circuit SKK Set room temp. Heating season Room temperature Cooling period...
Contact your local contractor if you have any questions regarding the maintenance and repair of your system. You may, for example, find local contractors on the internet under www.viessmann.com. Viessmann Werke GmbH&Co KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford...
Page 12
Contact your local contractor if you have any questions regarding the maintenance and repair of your system. You may, for example, find local contractors on the internet under www.viessmann.com. Viessmann Werke GmbH&Co KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford...