Version - Viessmann VITOTRONIC 200 Service Instructions Manual

Heat pump control unit
Table of Contents

Advertisement

Appliance types
(cont.)
Air/water heat pumps for indoor and outdoor installation, monoblock version
All components of the refrigerant circuit are installed in
a single appliance.
Heat pumps for indoor installation
The heat pump is supplied with outdoor air via an air
duct. Expelled air leaves the building via another air
duct.
The refrigerant circuit has a variable speed compres-
sor. The secondary pump, the 3-way diverter valve
"central heating/DHW heating" and the heat pump con-
trol unit are built into the heat pump.
Overview of system components and functions for air/water heat pumps for indoor or outdoor installa-
tion, monoblock version
System com-
Page
ponent/func-
tion
Heating/cool-
48
ing circuits
Instantaneous
39
heating water
heater
External heat
38
generator
Heating water
43
buffer cylinder
Heating water/
43
coolant buffer
cylinder
Central heat-
48
ing
Room cooling
55
DHW heating
40
Heat pump
29
cascade
Swimming
56
pool heating
Mechanical
57
ventilation
Photovoltaics
69
Smart Grid
35
Air/water heat pumps with indoor and outdoor unit, split version
The heat pumps comprise an outdoor unit for installa-
tion outside the building and an indoor unit for installa-
tion inside the building.
Heat pump for indoor installation
Vitocal 200-A
In conjunction with buffer cylinder:
A1/HC1
M2/HC2: Mixer motor directly control-
led
M3/HC3: Mixer motor controlled via
KM-BUS
Factory-fitted
X
X
X
X
X
Separate DHW cylinder
X
X
X
X
X
Heat pumps for outdoor installation
The heat pump is installed outdoors. The building is
heated or cooled via the hydraulic connection lines.
These hydraulic connection lines, together with the
electrical connecting cables, are laid in the ground with
frost protection.
The heat pump control unit is located in a separate
enclosure inside the building. The hydraulic compo-
nents for distribution in the secondary circuit, such as
the secondary pump, are also installed in the building.
Heat pump for outdoor installation
Vitocal 300-A
In conjunction with buffer cylinder:
A1/HC1
M2/HC2: Mixer motor directly controlled
M3/HC3: Mixer motor controlled via KM-
BUS
Depending on type, supplied on site or
accessories
Depending on type
Separate DHW cylinder
Depending on type
Except for the condenser, all components of the refrig-
erant circuit are located in the outdoor unit, including
the refrigerant circuit controller.
Introduction
X
X
X
X
X
X
X
X
17