Line differential protection
Table of Contents

Advertisement

Additional information for additional ports (bottom side of device, front, port B)
DNP3.0, optical, 820 nm, ST connector
IEC 60870-5-103, redundant, electrical RS485, RJ45 connector
IEC61850, 100Mbit Ethernet, 2 electrical ports, RJ45 connector
IEC61850, 100Mbit Ethernet, 2 optical ports, LC-duplex- connector
Converter
SIEMENS OLM
1)
SIEMENS OLM
1)
1)
The converter requires an operating voltage of 24 VDC. If the available operating voltage is > 24 VDC the additional
power supply 7XV5810–0BA00 is required.
Additional communication interfaces for port A (bottom side of device, rear)
no additional
1)
Redundant optical fiber protection interface to 2-wire protection interface
Protection interface optical fiber for monomode (24 km) (14.9 mi.)/multimode fiber (4 km) (2.5 mi.), LC
duplex connector
2)
1)
Already equipped with optical fiber protection interface if MLFB pos. 6 = 1,2,5 or 6
2)
Deliverable only in combination with 6th position = 3 or 7
Measurement / Fault Recording
With fault recording
With fault recording, average values, min/max values
Protection functions
ANSI-Nr
Description
Basic design (included in all versions)
87L/87N L
Line differential protection (phase comparison and 3I0 differential protection)
Inrush current detection
50 TD/51
Overcurrent protection phase 50-1, 50-2, 50-3, 51
50N TD/51N
Overcurrent protection ground 50N-1, 50N-2, 50N-3, 51N
49
Thermal overload protection (49)
74TC
Trip circuit supervision
50BF
Circuit-breaker failure protection
86
Lock out
Circuit breaker transfer trip
External trip initiation
Cold load pickup (dynamic setting changes)
Monitoring functions
Circuit breaker test
Circuit breaker control
Flexible protection functions from current, voltage, power
27/59
Undervoltage/overvoltage 27, 59
81 U/O
Underfrequency / overfrequency
Basic design + directional overcurrent protection phase and directional ground fault protection
67
Overcurrent protection, directional phase ∠(V, Ι) 67-1, 67-2, 67-TOC
67N
Ground fault protection, directional ∠(V, Ι) 67N-1, 67N-2, 67N-TOC
Basic design + ground fault differential protection in resonant-grounded/isolated systems
87Ns L
Ground fault differential protection in resonant-grounded/isolated systems
SIPROTEC 4, 7SD80, Manual
E50417-G1100-C474-A2, Edition 02.2018
Order number
6GK1502–2CB10
6GK1502–3CB10
2)
2)
2)
Ordering Information and Accessories
A.1 Ordering Information 7SD80 V4.7
Zusatz
+ L 0 H
+ L 0 P
+ L 0 R
+ L 0 S
Use
for single ring
for double ring
Pos. 12
0
7
Pos. 13
1
3
Pos. 15
A
1)
B
1) 3)
C
3) 4)
301