Appendix4.5 Microcomputer program
Since the QCPU-A do not have the microcomputer mode, the utility software packages
and user-created microcomputer programs used for the A1SHCPU and A2SHCPU are not
available. The microcomputer program area of the QCPU-A is dedicated for the SFC.
When the utility software packages or the microcomputer programs above are used,
delete all of the SUB instructions (microcomputer program call) used for executing them
from the sequence program.
When the following utility packages are used, modify the program using the QCPU-A
dedicated instructions.
1) SW
2) SW
3) SW
4) SW
5) SW
-UTLP-FNO.................... Type AnSHCPU/AnACPU/AnUCPU/QCPU-A (A
-UTLP-PID...................... Type AnACPU/AnUCPU/QCPU-A (A Mode)
-SIMA
-UTLP-FDI
Unusable
-SAPA
App - 52
mode) Programming Manual
(Dedicated Instructions) IB-66251
Programming Manual
(PID Control Instructions) IB-66258