Number
Name
D9196
D9197
Faulty station
detection
D9198
D9199
Table App.2.2 Special Register List (continued)
Description
• Bit which corresponds to faulty I/O module or remote
terminal module is set (1).
(Bit which corresponds to a faulty station is set when
normal communication cannot be restored after
executing the number of retries set at D9174.)
• If automatic online return is enabled, bit which
corresponds to a faulty station is reset (0) when the
Bit pattern of the
station is restored to normal.
faulty station
• Data configuration
Address
Station
D9196
Station
D9197
Station
D9198
Station
D9199
POINTS
(1) The contents of special registers are all cleared when power supply is turned
off regardless of latch clear operation or reset operation using the reset key
switch. The contents are retained when the RUN/STOP key switch is set to
STOP position.
(2) The contents of special registers marked *1 are not cleared even if normal
status is recovered. Use any of the following methods to clear the data.
(a) Method by user program
Insert the circuit shown at right into
the program, and turn on the clear
execution command contact to clear
the contents of registers.
(b) Method by peripheral device
Set the register to "0" by changing the present value with the test function
of peripheral device or set to "0" by forced reset. For the operation
method, refer to the Instruction Manual for each peripheral device.
(c) By moving the RESET key switch at the CPU module front to the RESET
position, the special register is set to "0".
(3) Data is written to the special registers marked *2 in the sequence program.
(4) Data is written to the special registers marked *3 in test mode of the
peripheral device.
b15
b14
b13
b12
b11
b10
b9
b8
b7
Station
Station
Station
Station
Station
Station
Station
Station
16
15
14
13
12
11
10
9
8
Station
Station
Station
Station
Station
Station
Station
Station
32
31
30
29
28
27
26
25
24
Station
Station
Station
Station
Station
Station
Station
Station
48
47
46
45
44
43
42
41
40
Station
Station
Station
Station
Station
Station
Station
Station
64
63
62
61
60
59
58
57
56
App - 45
Details
b6
b5
b4
b3
b2
b1
b0
Station
Station
Station
Station
Station
Station
Station
7
6
5
4
3
2
1
Station
Station
Station
Station
Station
Station
Station
23
22
21
20
19
18
17
Station
Station
Station
Station
Station
Station
Station
39
38
37
36
35
34
33
Station
Station
Station
Station
Station
Station
Station
55
54
53
52
51
50
49
1: Error
0: Normal
Clear execution
command
RST
Special function register to be cleared
Usable with
A2C and A52G.
D9005

Hide quick links: