Mitsubishi Electric MELCEC Q Series User Manual page 232

A mode
Table of Contents

Advertisement

APPENDICES
Number
Name
*1
D9100
*1
D9101
*1
D9102
*1
D9103
*1
D9104
*1
D9105
Fuse blown
*1
module
D9106
*1
D9107
*1
Fuse blow
D9100
module
*2
D9108
*2
D9109
*2
D9110
Step transfer
*2
monitoring
D9111
timer setting
*2
D9112
*2
D9113
*2
D9114
*:
Usable with AnN and AnA which are compatible with SFC.
For the AnN and AnA which are compatible with SFC, refer to the MELSAP-ll Programming Manual.
Table App.2.2 Special Register List (continued)
Description
• Output module numbers (in units of 16 points), of
which fuses have blown, are entered in bit pattern.
(Preset output module numbers when parameter
setting has been performed.)
D9100
D9100
D9101
D9101
D9107
D9107
Turns on all the bits corresponding to the output
module number (in units of 16 points) in output points
occupied by the modules on modules with more than
Bit pattern in units of
16 output points.
16 points of fuse blow
(Example) On a module with 64 points attached to
modules
• Fuse blow check is executed also to the output module
of remote I/O station.
(If normal status is restored, clear is not performed.
Therefore, it is required to perform clear by user
program.)
(For the AnU, A2US(H) and QCPU-A (A mode))
• Data clear of D9100 to D9107 is executed by turning
off M9000 (fuse blown).
(For the CPU other than the AnU, A2US(H) and QCPU-
A (A mode))
• Data clear of D9100 to D9107 is executed by turning
off D9100 to D9107 (fuse blown).
• Stores the output module number of the fuses have
blown in the bit pattern.
Fuse blow module bit
pattern
• Sets value for the step transfer monitoring timer and
the number of F which turns on when the monitoring
timer timed out.
Timer setting value
and the F number at
time out
(By turning on any of M9108 to M9114, the monitoring
timer starts. If the transfer condition following a step
which corresponds to the timer is not established within
set time, set annunciator (F) is tuned on.
Details
15 14
15 14
13
13
12 11
12 11
10 9 8
10 9 8
7
7
1
0 0 1
0 0
0 0
0
0
0
0
0 0
0
0
(YC0)
(Y80)
1
1
0
0
0
0
0 0
0 0
0 0
0 0
0
0
(Y1F0)
(Y1A)
1
0 0
0 0
0
0
0
0
0 0 0
0 0 0
0
0
Y7
BC
Indicates fuse blow.
slot 0, b3 to b0 turn on when a fuse blow
is detected.
b15
b8 b7 b6 b5 b4 b3 b2 b1
D9100
0
0
0 is fixed.
Indicates the module
for setting switch 2.
Indicates the module
for setting switch 3.
Indicates the module for setting
switch 4 or the module for
extension base unit slot 0.
Indicates the module for setting
switch 5 or the module for
extension base unit slot 1.
Indicates the module for setting
switch 6 or the module for
extension base unit slot 2.
Indicates the module for setting switch 7 or
the module for extension base unit slot 3.
b15 to b8 b7 to b0
Timer setting
(1 to 255 sec
in seconds)
F number setting
App - 38
Applicable CPU
6 5 4 3 2 1 0
6 5 4 3 2 1 0
0 0 0 0 0 0 0
0 0 0 0 0 0 0
0 0 0 0 0 0 0
0 0 0 0 0 0 0
1 1
0 0 0
0 0 0
0 0 0
0 0 0
Y7
30
Usable with all
types of CPUs
b0
Indicates the module
for setting switch 0.
Indicates the module
for setting switch 1.
Dedicated to
A0J2H.
Usable with AnN ,
AnA, AnU, A2AS,
AnA board,
QCPU-A (A
Mode), A2C,
A0J2H, AnS,
AnSH, A1FX and
A52G.
Only remote
I/O station
information
is valid for
A2C.