Mitsubishi Electric MELCEC Q Series User Manual page 37

A mode
Table of Contents

Advertisement

2.
SYSTEM CONFIGURATION
Product Name
Model Name
A1SJ71LP21
A1SJ71LP21GE
MELSECNET/10
data link
module
A1SJ71BR11
A1SJ71LR21
CC-Link system
A1SJ61BT11
master module
MELSECNET/
MINI-S3 master
A1SJ71PT32-S3
module
MELSECNET-I/
O LINK master
A1SJ51T64
module
S-LINK
interface
A1SJ71SL92N
module
AS-I interface
A1SJ71AS92
module
Positioning
detection
A1S62LS
module
Programmable
controller easier
A1SS91
monitoring
module
Memory card
interface
A1SD59J-S2
module
Simulation
A6SIM-X64Y64
module
Description
For the control, master, and normal stations of
the MELSECNET/10 data link module system
(For the dual loop SI-type optical fiber cable)
For the control, master, and normal stations of
the MELSECNET/10 data link module system
(For the dual loop GI-type optical fiber cable)
For the control, master, and normal stations of
the MELSECNET/10 data link module system
(For the single bus coaxial cable)
For the control, master, and normal stations of
the MELSECNET/10 data link module system
(For the coaxial cable dual loop)
For the master and local stations of the CC-Link
data link system
(For the twisted pair shield cable only)
For MELSECNET/MINI-S3 master stations
(max. 64 stations). Performs remote I/O and
remote terminal control of a total of 512 I/O
points.
MELSECNET-I/O LINK master station. Controls
I/O LINK remote I/O module of a maximum of
64 stations and a total of 128 I/O points.
If only a few remote I/O modules are used,
perform I/O assignment with a peripheral device
to decrease the number of occupied I/O points
to 16, 32, or 48.
Master module for S-LINK
I/O total 128 points
Master module for AS-I
I/O total 496 points
Absolute positioning detection module
Programmable controller easier monitoring
module
Memory card interface module
An I/O simulation module used connected to the
base unit Debugging can be executed without
connecting the I/O module to the base unit. Use
an extension cable of the AnS series between
the main base of the AnS series and the
A6SIM-X64Y64.
Number of Occupied
Points (points)
[I/O Assignment
Module Type]
[32 special
32
points]
[32 special
32
points]
[32 special
32
points]
[32 special
32
points]
[32 special
32
points]
I/O mode
32 [32 special points]
Expanded mode
48 [48 special points]
[64 output
64
points]
[32 special
32
points]
[32 special
32
points]
[32 special
32
points]
[16 output
16
points]
[32 special
32
points]
64
[64 input points]
64
[64 output
points]
2 - 16
Current Consumption
Remark
5VDC(A) 24VDC(A)
0.65
0.65
0.80
1.14
0.40
0.35
0.115
0.09
0.20
0.15
0.55
0.08
The current
consumption
0.05
describes in
connecting
A1SD59J-MIF.
TYP. 0.3
(When all
points
"ON")

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qcpu-a seriesQ02cpu-aQ02hcpu-aQ06hcpu-a

Table of Contents