Image And Result View - Siemens SIMATIC MV500 Operating Manual

Optical identification
Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Application
5.1 Program
5.1.7

Image and result view

Image view
You specify the settings for the image display in this group.
Table 5- 62
Image view
Parameter/
button
Source
Show live image
(continuously)
Show trigger im-
age
(triggered)
Fire trigger
Show archive
image
Overlay
Archive / Show
Load image
Save image
96
Description
Selection of image source
Restriction: This function can only be performed in the "Edit" status.
Shows the live image continuously in the image display.
Shows acquired images activated by a trigger in the image display.
The reader acquires images only if this is activated by the trigger source, for example, a light
barrier.
Requirements: The "Show trigger image" function was previously selected and you have the
"Take control" authorization. You do not need the authorization with the "Edit" status.
Manual triggering of an image acquisition.
Shows archive images of the images saved on the reader in the image display.
Enables/disables the superimposed view of live image and archive image. This view can be used
to match two acquired images, for example, to restore the orientation of the reader
The function depends on the current reader status.
In processing mode ("Start" status), you can use the "Show" parameter to set a filter function that
determines which image types are displayed in the image display.
In all other operating modes, the "Archive" parameter below the image display shows all images
stored in the saved programs.
Restriction: This function can only be performed in the "Edit" status.
Loads a saved image (*.bmp, *.zip) onto the optical reader
Note that the processing result can be highly impaired if the resolution of the uploaded image
does not match the resolution of the reader version.
Restriction: This function cannot be performed in the "Stop" status.
Saves the currently displayed image on your PC. If the "Improve image" parameter is enabled,
the improved image is also saved.