5.1.5.2

Error messages

In this group, you define which text is displayed for the respective error in the WBM and is
output via the text interface.
You enter the individual characters of each error text just as you enter the characters in the
"Format text" input box with the following exception: If you want to display a percentage
character, enter "%%" here.
Table 5- 60
Error messages
Menu command or
parameter
Read error
Filter error
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
Possible values
Default
See "Description"
Read Error(%s)
column
See "Description"
Filter Error(%s)
column
Description
Content and format of the string to be output in the
event of read errors.
The string can be a maximum of 100 bytes long. The
string consists of any combination of the following
elements:
Characters whose ASCII equivalent is between
"01H" and "FFH" ("%%" causes a percentage
character to be output)
Formatting instructions for output of variables
The following formatting instructions are possible:
%s
%c
%b
%i
"%s" stands for the textual description of the proba-
ble cause of the error in English.
"%c" stands for a decimal digit with the same infor-
mation content.
%b stands for the error message of the binary result
of a read.
%i stands for the trigger ID.
Content and format of the string to be output in the
event of read errors.
The string can be a maximum of 100 characters
long. The string consists of any combination of the
following elements:
Characters whose ASCII equivalent is between
"01H" and "FFH" ("%%" causes a percentage
character to be output)
Formatting instructions for output of variables
The following formatting instruction is possible:
%s
"%s" stands for the textual description of the proba-
ble cause of the error in English.
Application
5.1 Program
89