Diagnostics & Monitoring - Siemens SIMATIC MV500 Operating Manual

Optical identification
Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Settings
6.2 Options
Relationships and dependencies of the parameters
Table 6- 17
Parameter
All parameters on
this page
6.2.2
Diagnostics & monitoring
In this area, you determine the information to be stored for diagnostic purposes.
Logging
In this group, you specify the images to be stored in the reader and their form. Including:
● Saving images in the reader
● Saving diagnostic events in the reader
Note
Saving diagnostic data
Save your diagnostic data before you change the reader to adjustment mode.
If you have set the buffer type "Ring" for logging pictures, pictures acquired in adjustment
mode can overwrite pictures you have already recorded.
122
Relationships and dependencies of the parameters
Dependency
Program
Verification > Calibration
Run
Description
In case of changes on this page, note:
As a result of this operation, programs and
calibrations that use this lamp (internally or
externally) are marked as non-executable.
In order to use a non-executable program
again, you must check the exposure set-
tings and save the program again.
In order to use a non-executable calibra-
tion again, you must repeat the calibration
process and save the calibration again.
If you reconnect the lamp used for the calibra-
tion without changing the parameters and
select it in the lighting options, the calibration
will be executable again.
Operating Manual, 05/2019, C79000-G8976-C495-02
SIMATIC MV500

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents