6.2

Options

6.2.1

Lighting

In this area, you determine the internal or external lighting to be used. For lamps with which
the reader is unfamiliar, you define which properties the connected lamps have.
NOTICE
An incorrectly selected lamp can cause an overload
Select the lamp being used under "Settings > Options > Lighting".
Only in this way can the internal overload protection ensure that the limit values for duty
cycle and maximum flash duration are adhered to.
An incorrectly selected lamp can lead to its overload and destruction in the long term.
Internal lamp / External lamp
Note
Changes to the connected lamp/connecting a different lamp:
Programs and calibrations no longer executable
Note that when you subsequently change the parameters of a selected lamp or connect and
select a different lamp, all programs and calibrations that use these lamps (internally or
externally) are marked as non-executable.
• In order to use a non-executable program again, you must check the exposure settings
and save the program again.
• In order to use a non-executable calibration again, you must repeat the calibration
process and save the calibration again.
If you reconnect the lamp used for the calibration without changing the parameters and
select it in the lighting options, the calibration will be executable again.