Application
5.1 Program
Info statistics
The "Info statistics" group is shown automatically as soon as a program is started.
The statistical information on the relevant number of processing procedures and reads is
provided as percentage (%).
Table 5- 65
Menu command or
parameter
Total counter
Temporary error
Read
NOK
Match (only when
Match = Use)
Quality evaluation
Good evaluation
Fair evaluation
Poor evaluation
Trigger too fast
Trigger interval
100
Info statistics
Description
Absolute number of total processing procedures
Number of temporary errors that have occurred or number of invalid trigger sig-
nals.
The trigger signals are valid only when the last image acquisition or the set
number of image acquisitions in the "Scan" mode is completed.
Note:
Temporary errors can be deleted by going to the page "Info > Diagnostics >
Reset data records".
Absolute number of successful image processing procedures
Relative number of successful image processing procedures
Absolute number of unsuccessful image processing procedures
Relative number of unsuccessful image processing procedures
Absolute number of reads with a positive match result
Relative number of reads with a positive match result
The statistical distribution of the overall quality evaluation of the past processing
procedures is displayed. The evaluations are "Good", "Fair" and "Poor".
Absolute and relative number of image processing procedures in which the
quality evaluation was "Good". To decode with the quality "Good", the code does
not need to be completely in the ROI.
Absolute and relative number of image processing procedures in which the
quality evaluation was "Fair".
Absolute and relative number of image processing procedures in which the
quality evaluation was "Poor" or in which a verification error occurred.
Absolute and relative number of image processing procedures during which the
next trigger signal came too fast.
Time interval between two trigger pulses (format: hh:mm:ss.ms)
Min.: Minimum of the trigger intervals since the last startup (format:
hh:mm:ss.ms)
Max.: Maximum of the trigger intervals since the last startup (format:
hh:mm:ss.ms)
Average: Average of the trigger intervals since the last startup (format:
hh:mm:ss.ms)
Operating Manual, 05/2019, C79000-G8976-C495-02