Table 5- 38
Decoding order
Parameter
Possible values
Decoding order
2D codes
DMC
DotCode
PDF417
QR
1D codes
CodaBar
Code 32
Code 39 (no checksum)
Code 39+CS (with check-
sum)
Code 93
Code 128
EAN 8
EAN 13
GS1 DataBar Expanded
GS1 DataBar Limited
GS1 DataBar Omnidirec-
tional
GS1 DataBar Stacked
Int. 2/5 (no checksum)
Int. 2/5+CS (with checksum)
Pharmacode (0°)
Pharmacode (180°)
Postnet
UPC-A
UPC-E
Code type
Saved
Dynamic
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
Default
Description
DMC
Select and sort the code types required in your
application.
You can use the buttons to add new code types or
remove them:
"Add code type"
Opens a shortcut menu where you select a
code type. The code type is inserted in the list
below the currently selected position.
"Remove selected code type"
Removes the respective code type from the
list.
You can change the order of the codes with 'drag-
and-drop'.
Saved
If the code type is known in your application and
does not change, select the "Saved" option in the
drop-down list.
If the code type can change during operation,
select "Dynamic".
Note
The "Dynamic" setting cannot be used together
with the code types "Dotcode", "QR" or "PDF417",
or the decoder type "ID-Genius".