Application
5.1 Program
5.1.2.1

Auto-setup

The Auto-setup functions assist you in the parameter assignment of a new or existing
program. You have the option of having the parameters assigned automatically or making
the settings manually.
Table 5- 6
Menu command or
parameter
Fast code type
detection
Fast focus detec-
tion
Full program
Step-by-step
adaption
24
Auto-setup
Description
You use this parameter to specify whether or not Fast code type detection is to
be performed for the subsequent adaptation. You define the default setting for
this parameter in the menu "Settings > Options > Extras > Operation on the
device".
On: Code type detection is automatically performed for the following code types
if decoder steps are present in the source program:
DMC (with set decoder type)
Available 1D codes (except pharma code)
Off: Complete code type detection for the following code types is performed for
each decoder step:
DMC (with currently set decoder type)
PDF417
Available 1D codes (except pharma code)
QR
DMC (with decoder type "ID-Genius", if not already done in step 1 and com-
patible with other settings)
You use this parameter to specify whether or not Fast focus detection is to be
performed for the subsequent adaptation. You define the default setting for this
parameter in the menu "Settings > Options > Extras > Operation on the device".
On: With focus detection, the image display or ROI area is not subdivided into
subROIs. This means that lighting and focus are not checked and adjusted for
each individual subROI. This setting shortens this process step. Recommended
for even, flat object holders.
Off: The image display or ROI area is divided into subROIs. This means that
lighting and focus are checked and adjusted for each individual subROI. Rec-
ommended for uneven object holders.
Automatically executes all adaption/program steps of the program. This may
take some time.
Note: This function is the same function that is triggered with the "READ" button
on the reader.
The adaption step is shown in the right column (image and result view).
Guides you through the program settings step-by-step. You can follow this adap-
tion through all adaption/program steps and either set the parameters manually
or have them adapted automatically.
Operating Manual, 05/2019, C79000-G8976-C495-02