Settings
6.2 Options
Parameter
Possible values
Fast code type
•
detection
•
Fast focus
•
detection
•
Target program
•
•
•
•
•
•
132
Default
On
Off
On
Off
Off
On
Next free program
Next free program
Current program
1
2
...
15
Description
On: Code type detection is automatically per-
formed for the following code types if decoder
steps are present in the source program:
DMC (with set decoder type)
•
Available 1D codes (except pharma code)
•
Off: Complete code type detection for the follow-
ing code types is performed for each decoder
step:
DMC (with currently set decoder type)
•
PDF417
•
Available 1D codes (except pharma code)
•
QR
•
DMC (with decoder type "ID-Genius", if not
•
already done in step 1 and compatible with
other settings)
On: With focus detection, the image display or
ROI area is not subdivided into subROIs. This
means that lighting and focus are not checked
and adjusted for each individual subROI. This
setting shortens this process step. Recommended
for even, flat object holders.
Off: The image display or ROI area is divided into
subROIs. This means that lighting and focus are
checked and adjusted for each individual subROI.
Recommended for uneven object holders.
Selection of the optical reader target program that
is overwritten by default when pressing the
"READ" button.
Operating Manual, 05/2019, C79000-G8976-C495-02