5.1.4.2

General

Table 5- 23
General
Parameter
Possible values
Step name
--
ROI position
Fix
Follow step x
Verification
Uncalibrated
Calibrated
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
Default
Description
Decoder
In this text box, enter the name of the currently se-
lected decoder step.
Possible values: Letters, numbers, underscores,
spaces, parentheses, punctuation marks and other
special characters (ASCII range 32...127). Maximum
of 255 characters.
Fix
Fix
The ROI position remains unchanged as set here:
The "Follow step x" entries are available from the
second step and refer to the processing steps before
the step that is currently being edited.
Follow step x
The ROI position follows the shift of the read result
of step x during processing. Only a translational shift
takes place, no rotary tracking.
--
Display of the verification which was specified in the
"Verification" group of the "Image acquisition" pro-
gram step.
Click on the "Change" link to change the verification.
This automatically calls the "Image acquisition" pro-
gram step in which you can change the verification.