Roland R1000 Series Manual page 88

Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Start-up
System parameter 11: Specifying the number of active channels.
system parameter: 11
number of
active channels
Fig. 75: Specifying the number active channels
For L20-XX-S the number of measuring channels cannot be changed.
For L20-3-XX-S it is possible to set the number of the measuring stations between 1 and 3.
System parameter 12: Specifying the type of sensor.
system parameter: 12
sensor type
LAAS40
Fig. 76: Specifying the type of sensor
Selectable options:
LAAS10 (in preparation)
LAARS10 (do not use)
LAAS10+ (in preparation, only for L20-3-XX-S)
LAAS40
LAAS40+ (only for L20-3-XX-S)
LAARS40 (do not use)
LAAS200 (in preparation)
LAAS200+ (in preparation, only for L20-3-XX-S)
LAARS200 (do not use)
System parameter 13: Specifying the moving average.
system parameter: 13
default moving average
Fig. 77: Specifying the moving average
The moving average value which is set in "clear program parameters" as default for for all programs
must be entered here. This value will be used in case the existing program parameters are deleted
and therefore no appropriate moving average value exists.
88
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
1
Note
When using one pair of sensors connect these to channel 1.
When using two pairs of sensors connect these to channel 1 and 2.
Note
The connected sensor type and the selected sensor type is
checked each time the unit starts. If the sensors do not match, an
error will be reported.
50 ms
Manual
B0063191 / 1.3